whatsapp: 0086-18615575385
whatsapp: 0086-13668821631

Finned Tube Heat Exchanger Water/Air Didactic Equipment Vocational Training Equipment Thermal Lab Equipment

Item No.: ET 300
Finned Tube Heat Exchanger Water/Air Didactic Equipment Vocational Training Equipment Thermal Lab Equipment
Description
ET 300 Finned Tube Heat Exchanger Water/Air Didactic Equipment Vocational Training Equipment Thermal Lab Equipment

Function of the heat exchanger as an air heater or water cooler
Features
- convective heat transfer between water and air
- closed hot water circuit
Learning objectives/experiments
- familiarisation with the heat transfer process between water and air
- determination of heat flows from water and air
- determination of the efficiency or losses
- energy balances at the heat exchanger
- plot pump characteristic
Specification
[1] finned-tube heat exchanger to study convective heat transfer between water and air
[2] function of the heat exchanger as an air heater or water cooler
[3] closed hot water circuit with electric heater, thermostat, water tank and pump
[4] adjustable water and air flow
[5] determination of the air volumetric flow rate by differential pressure at measuring nozzle
[6] digital display of temperatures, flow rates and pressure
[7] software for data acquisition via USB under Windows 10


Technical data
Finned-tube heat exchanger
- material: Cu/Al
- average transfer surface: 2,80m2 (air side)
- output: 2kW
- water temperature: 70°C
Pump
- power consumption: 470W
- max. flow rate: 4,2m3/h
- max. head: 20,5m
Fan
- power consumption: 0,25kW
- max. flow rate: 13m3/min
- max. pressure difference: 430Pa
Water tank: 28L
Heater: 2kW
Thermostat: max. 80°C
Measuring ranges
- temperature: 4x 0...100°C
- flow rate: water 0...6m3/h
- pressure: water 0...4bar abs.
- mass flow rate: air 0...250g/s
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 230V, 60Hz, 3 phases
UL/CSA optional
LxWxH: 1730x800x1900mm
Weight: approx. 220kg