Operating behaviour of an axial propeller pump Features - operating behaviour of an axial-flow pump - part of the FEMLine Learning objectives/experiments - in combination with HM 365 -- determination of the pressure/volume characteristics -- determination of the power requirement of the pump -- determination of the hydraulic power -- determination of the efficiency -- determination of the head -- determination of the system characteristics Specification [1] investigation of an axial-flow pump [2] closed water circuit [3] powered by HM 365 Universal drive and brake unit [4] water tank with sight glass [5] determination of the flow rate with the electromagnetic flow rate sensor [6] digital display of flow rate, pressure and temperature [7] software for data acquisition via USB under Windows 10 Technical data Pump - output: 1000W at 1000min-1 - max. flow rate: 700L/min - max. head: 1,75m Tank: 160L Measuring ranges - flow rate: 0...1200L/min - temperature: 0...100°C - pressure (inlet): ±1bar - pressure (outlet): 0...0,6bar 230V, 50Hz, 1 phase 230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase UL/CSA optional LxWxH: 1110x800x1380mm Weight: approx. 154kg